This eshop uses cookies to provide services, customize your ads, and analyze your traffic. Information concerning the terms of personal data protection can be found here

Více informací
Přijmout všechny cookies Personalizovat
Přijmout zvolené cookies

PH meter PH-A2

Kód: 7540-4116

Condition: New

PH meter PH-A2 - measures the acidity of water

2x new battery LR44 (1.5V) is part of the package - insert batteries see photo!

Kč190 s DPH
Kč157 bez DPH
Quantity
in stock

Kdy zboží dostanu?

Kdy zboží dostanu?

GLS parcel shop úterý 23. 4. 2024
GLS na adresu úterý 23. 4. 2024
Balíkovna úterý 23. 4. 2024
Zásilkovna CZ úterý 23. 4. 2024
Česká pošta - balík do ruky úterý 23. 4. 2024
DPD úterý 23. 4. 2024
Paketa SK na výdejní místo středa 24. 4. 2024
Paketa SK na adresu středa 24. 4. 2024
  • Našli jste lepší cenu?
  • Našli jste lepší cenu?

    * Povinná pole

    Odpovíme vám co nejdříve, zpravidla během pár hodin.

    Zavřít nebo  

    help_outlineZaslat dotaz

    Suitable for testing the pH of water in aquariums, swimming pools and more. This microprocessor-controlled PH tester is very accurate.

    Backlit LCD display 26 * 13mm, "pen" design. This PH tester is an ideal instrument for measuring the PH of water in the home, pool, etc.

    Clean the sensor at the bottom before use.

    Measurement: Switch on the device with the switch at the top. Remove the soda cover and immerse in water. Wait a few seconds for the displayed value to stabilize.

     

    Calibration: pour the powder into a clean glass, add 250ml of deionized water and mix. It is optimal to measure water at 25 ° C. If the measured PH differs from the specified value, deliver with the potentiometer on the back.

    Specifications:

    Measuring range: 0.00-14.00pH

    Resolution: 0.01pH

    Accuracy: ± 0.01pH

    Operating temperature: 0 ℃ ~ 60 ℃

    Calibration: automatic calibration of two points

    Power supply: 3

    2 * 1.5V battery LR44

    Size: 155 * 31 * 18 mm

    weight: 50g

    Package contains: measuring instrument, powder for meter calibration (pH 4.01 + pH 6.86), 2xLR44 batteries, English instructions

    Instructions for use:

    1) Remove the protective cap and the protective film on the display
    2) rinse the electrode with distilled water and dry
    3) turn on the device by holding down the ON / OFF button
    4) immerse the pH meter electrode in the test fluid (must not exceed the line)
    5) Stir lightly and wait approx. 30 seconds for the measured value to stabilize
    6) after the measurement, clean the electrode with clean water, switch off the device with the ON / OFF button and replace the protective cap

    Calibration

    1) turn on the device
    2) Dissolve the calibration powder in 250 ml of distilled water
    3) immerse the electrode in a solution with pH 6.86 (recommended water temperature around 25 ° C)
    4) press the CAL calibration button for 5 seconds
    - the display starts flashing with the displayed value 6.86
    -wait until the display stops flashing
    5) then clean the electrode with clean water
    6) apply the same procedure with pH 4.01 solution
    7) clean the electrode again with clean water
    8) test the calibration by immersing the instrument in solution, if it shows incorrectly repeat the procedure described above

    Recalibration is necessary in the following cases:
    - longer period of non-use
    - very frequent use
    - if you require very accurate measurements
    - the CAL button was pressed and the electrode was exposed to air for a long time

    Maintenance:
    always put the protective cap back on after use to prevent the electrode from drying out by prolonged exposure to air, this could lead to slower and less accuratemeasurement